Re: Adding cloned CalibrUI to BSP



Oh, I just think it is easier to copy/paste a few lines of the pbxml than to
add it using the GUI. I am old fashioned that way.

We don't have multiple copies of the code, we use our version control to
manage one set of code and just put it in multiple places on the hard disk
to build it.

--
Bruce Eitman (eMVP)
Senior Engineer
beitman AT applieddata DOT net

Applied Data Systems
www.applieddata.net
An ISO 9001:2000 Registered Company
Microsoft WEP Gold-level Member

"Michael Reim"
<nospammichaelDOTreim@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx> wrote in
message news:uJ1Ar3s6HHA.484@xxxxxxxxxxxxxxxxxxxxxxx
Hello Bruce

Thanks again, it appears its always you, who knows the solution.

I copied the cloned calibrui into the other workspace directory and called
"Project\Insert\Existing Project" to add it to the workspace.
It worked without any modification, so I don't know, why you have to
modify the pbxml file.

I don't like to copy the same source to different places, but if this is
the only way to do it, then its ok.

--
Michael Reim
Michael DOT Reim AT helmut-fischer DOT de


"Bruce Eitman [eMVP]" <beitman.nospam@xxxxxxxxxxxxxxxxxxxxxx> schrieb im
Newsbeitrag news:ubSFW5j6HHA.4252@xxxxxxxxxxxxxxxxxxxxxxx
We also tried, but with no success. The problem is that GWEs is build
prior to your BSP. That wasn't the case in 4.x, where the BSP did the
linking to create gwes.exe.

I just copy the Calibrui to the new project and cut and past the relevant
lines from one pbxml to the other.

--
Bruce Eitman (eMVP)
Senior Engineer
beitman AT applieddata DOT net

Applied Data Systems
www.applieddata.net
An ISO 9001:2000 Registered Company
Microsoft WEP Gold-level Member

"Michael Reim"
<nospammichaelDOTreim@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx> wrote
in message news:erNAV0h6HHA.5984@xxxxxxxxxxxxxxxxxxxxxxx
Hello all

What I have:
- My own BSP called MyBSP
- One workspace for testing called TreiberTest
- One workspace for our device called DeviceWS

In workspace TreiberTest I have cloned CalibrUI according to the online
help.
This resulted in a directory
E:\WINCE500\PBWorkspaces\TreiberTest\CalibrUi.
The cloned version runs ok in this workspace (one minor problem still to
solve).

Now I want this cloned version to run on the workspace DeviceWS and
maybe on some others in the next future.
So I copied E:\WINCE500\PBWorkspaces\TreiberTest\CalibrUi to
E:\WINCE500\PLATFORM\MyBSP\CalibrUi and added this to the workspace
DeviceWS by selecting "Project/Insert/Existing Project" from the menu.

If I now sysgen DeviceWS, I get the error message
NMAKE : fatal error U1073: don't know how to make
'E:\WINCE500\PBWorkspaces\DeviceWS\WINCE500\MyBSP_ARMV4I\oak\lib\ARMV4I\retail\calibrui_clone.lib'
How to resolve this?

Is there another recommended way to clone calibrUI and to add it as a
component to a BSP?

My goal is to end up with a cloned calibrUI as part of my BSP, which I
can "Add to OS Design" to every platform (workspace) derived from MyBSP.

PD5.0, ARM

TIA
--
Michael Reim
Michael DOT Reim AT helmut-fischer DOT de








.



Relevant Pages

  • Re: question: environment in workspace and platform.bat
    ... you mean the environment in workspace is set after *.bat in BSP?? ... maybe I need to check is there any other *.bat file for me to judge. ... beitman AT applieddata DOT net ...
    (microsoft.public.windowsce.platbuilder)
  • Re: Adding cloned CalibrUI to BSP
    ... That wasn't the case in 4.x, where the BSP did the linking to ... One workspace for testing called TreiberTest ... One workspace for our device called DeviceWS ... My goal is to end up with a cloned calibrUI as part of my BSP, ...
    (microsoft.public.windowsce.platbuilder)
  • Re: Development strategies
    ... and you are suggesting that he start maintaining a dozen BSPs. ... workspace because I need to modify a driver. ... Now I've a unique BSP that is dinamically configured based on ... and even if I perform a 'dir' command from a DOS prompt. ...
    (microsoft.public.windowsce.platbuilder)
  • Re: commit or rollback a transaction without first beginning a transaction
    ... "david epsom dot com dot au" wrote in message ... > other than the default workspace. ... >> opening separate database or workspaces and running transactions. ... >> Allen Browne - Microsoft MVP. ...
    (microsoft.public.access.modulesdaovba)
  • Re: 4.2 Help!!!
    ... beitman AT applieddata DOT net ... I created a workspace based on CEPC BSP in Windows CE 4.2. ... any alternate option is available?? ...
    (microsoft.public.windowsce.platbuilder)