Re: Platform builder packets data

Tech-Archive recommends: Repair Windows Errors & Optimize Windows Performance




--------------------
Thread-Topic: Platform builder packets data

I found out a strange thing. All DBGMSG right packets (sent by WinCE
inside
the resource kit) have a debug message with 00 at the end. Packets send
by my
device have messages without this ending character. Could that be the
problem? Yes, It can be a nonsense, but I try everything. And can I
somehow
influence it?



The messages should be null terminated.

Can you post a network capture of the connection attempt?

The debugger service connection attempts from PB are probably unrelated.
PB is quite persistent about trying to get a connection to the device and
will retry every few seconds to establish a connection with KD on the
device. You can stop this by going to the Target Configuration dialog and
setting the Debugger to None instead of KDstub.

---
This posting is provided "AS IS" with no warranties, and confers no rights.
You assume all risk for your use.

.



Relevant Pages

  • VS 2005, WinCE 5.0, debug ethernet, activesync - explosion mix!
    ... Activesync or use ethernet lan card. ... WinCE lan card is working propelly, I can ping, copy data over network, ... connection state is always ESTABLISHED. ... device I get that IP associated to "VMINI1" adapter. ...
    (microsoft.public.dotnet.framework.compactframework)
  • Thread Scheduling Problem ( WinCE 6.0)
    ... connection through TCP Connect Transport and specific IP address. ... if I stop sending debugging messages or try to send them more ... where can I found the thread scheduler in WinCE 6.0 R2? ... In Cirrus's BSP? ...
    (microsoft.public.windowsce.platbuilder)
  • Re: WinCE 5.0 constant GPRS connection
    ... First I'm really sorry if I'm being a pain but learning C# and WinCE at same ... just to test things I tried to setup a connection via "network ... Chris Tacke, Embedded MVP ...
    (microsoft.public.windowsce.app.development)
  • Re: Addendum: Socket drops out between desktop and Emulator
    ... I found by expermentation that by placing a slight delay "Thread.Sleep;" ... connection to be maintained without error. ... Any ideas as to why a slight delay on the WinCe end (this solution works ... >>> Paul T. ...
    (microsoft.public.dotnet.framework.compactframework)
  • Re: How to Autodial using RNAApp.exe?
    ... functions around this you can easily check if the connection is still going ... In the ICS for WINCE 3.0 it shows the following kesy (but the ... I see in the Compatible Dialer documentation that a queue needs to be ... How can I tell the Compatible Dialer is working and creating the queue? ...
    (microsoft.public.windowsce.embedded)