Re: Windows CE 6.0 remote tools broken?



Hi Gary,

I appreciate your help. Check my response to Dean if you want. I will
check corecon over the weekend and get back to you.

Cheers,
Bevan

"Gary Swalling" wrote:

Hi Dean,
So KITL is the transport used by the debugger, and on top of that
platman/corecon is used by the remote tools and CETK. Is that right?

Thanks,
Gary

"Dean Ramsier" <ramsiernospam@xxxxxxxxxx> wrote in message
news:%23nANLZSUHHA.4404@xxxxxxxxxxxxxxxxxxxxxxx
Kitl is its own transport, it has nothing to do with Platman/Corecon.
This should have just worked, it sounds like something is corrupted in
your install. Try deleting all the named devices, then create a new one
(or use the default).

If you build a reference BSP that comes with the kit, are your
connectivity options ok?

--
Dean Ramsier - eMVP
BSQUARE Corporation


"Gary Swalling" <garret.swalling@xxxxxxxxxxxxxxxxxxx> wrote in message
news:eXNbPMIUHHA.4832@xxxxxxxxxxxxxxxxxxxxxxx
Hi B-Dawg,
The eval of CE6 (until it expires) is equivalent to the full version,
except for licensing....

VS2005 pro is what I'm using with CE6.

I'm using outlook express for the newsgroup and I have a button "New
Post" to start a new thread.

Have you included corecon in your platform? It's my understanding that
corecon replaces platform manager in CE6 as the mechanism for KITL to
operate.

Regards,
Gary

"B-Dawg" <B-Dawg@xxxxxxxxxxxxxxxxxxxxxxxxx> wrote in message
news:5BAC8FB9-69BE-42A3-90B4-8AE1FB5FBBB2@xxxxxxxxxxxxxxxx

Hi, Sorry this is a slightly different question but I can't find any way
to
start a new message thread.... (I even clicked on something that said
new
thread but nothing happened - firefox issue perhaps?)

I have an ARM board with a Cirrus EDB9302 processor. I have downloaded
their BSP for platform builder 6.0 and it compiles fine (in VS2005 with
platform builder 6.0) )and provides the correct output files etc. In
the
project properties I enable KTL and the kernel debugger and I also
select
debug mode as opposed to release for the build type. Everything seems
to
build fine - no errors etc. I can install the generated eboot loader
onto
the board through an application that came from Cirrus.

My problem is that under the target/connectivity options menu it does
not
show any options for download/transport/debugger. It just has "None" in
all
three boxes. I know I should get an option for ethernet in transport at
least along with some other options. What has gone wrong here? Is it
because this is the evaluation platform builder? I am running Visual
Studio
2005 professional edition. Do I need to uninstall Active Sync perhaps?
I've
already tried shutting it down and running multiple instances of VS2005.
There must be a setting I have missed somewhere.

Anyones help would be much appreciated.

Thank you


"alext@xxxxxxxxxxxxx" wrote:

I'm having lots of problems trying to connect to a CE 6.0 device using
the remote tools like registry viewer. The device is connected via
Ethernet and debugging via Visual Studio 2005 works fine. I haven't
been able to resolve it, after doing/checking the following:

- made sure KITL enabled build setting is on and all the KITL settings
in the connectivity options are checked.

-Tried debug and release builds

- I am trying to use KITL Tranpsort as transport and CESH as startup
server - I get the error "Unable to load device side components. Please
check server configuration settings". These settings worked fine under
CE 5.0 platform builder (and still does).

- tried running both the CE 5.0 and CE 6.0 versions of the remote tools
directly by launching the .exe's without success.

- I have tried all other remote connection methods/combos
(KITL/CESH/MANUAL) without success.

What should I check I should have component-wise in my build to get
this working - as far as I can tell, my build has the same components
as my CE 5.0 version.









.



Relevant Pages

  • Re: Windows CE 6.0 remote tools broken?
    ... check corecon over the weekend and get back to you. ... corecon replaces platform manager in CE6 as the mechanism for KITL to ... platform builder 6.0))and provides the correct output files etc. ... check server configuration settings". ...
    (microsoft.public.windowsce.platbuilder)
  • Re: Windows CE 6.0 remote tools broken?
    ... that would be able to do that (ie missing corecon if Gary is right). ... I think it might be time for a reinstall of platform builder and/or VS2005 ... corecon replaces platform manager in CE6 as the mechanism for KITL to ... check server configuration settings". ...
    (microsoft.public.windowsce.platbuilder)
  • Re: Windows CE 6.0 remote tools broken?
    ... of CoreCon structure. ... automatically running when I try remote tools. ... the KITL transport or whatever it is called which is independant. ... I can succesfully build an OS in platform builder CE 6.0, ...
    (microsoft.public.windowsce.platbuilder)
  • Re: Windows CE 6.0 remote tools broken?
    ... VS2005 pro is what I'm using with CE6. ... corecon replaces platform manager in CE6 as the mechanism for KITL to ... platform builder 6.0))and provides the correct output files etc. ... check server configuration settings". ...
    (microsoft.public.windowsce.platbuilder)
  • Re: Windows CE 6.0 remote tools broken?
    ... platman/corecon is used by the remote tools and CETK. ... corecon replaces platform manager in CE6 as the mechanism for KITL to ... platform builder 6.0))and provides the correct output files etc. ... check server configuration settings". ...
    (microsoft.public.windowsce.platbuilder)