RE: Windows CE 6.0 remote tools broken?
- From: B-Dawg <B-Dawg@xxxxxxxxxxxxxxxxxxxxxxxxx>
- Date: Tue, 13 Feb 2007 13:31:01 -0800
Hi, Sorry this is a slightly different question but I can't find any way to
start a new message thread.... (I even clicked on something that said new
thread but nothing happened - firefox issue perhaps?)
I have an ARM board with a Cirrus EDB9302 processor. I have downloaded
their BSP for platform builder 6.0 and it compiles fine (in VS2005 with
platform builder 6.0) )and provides the correct output files etc. In the
project properties I enable KTL and the kernel debugger and I also select
debug mode as opposed to release for the build type. Everything seems to
build fine - no errors etc. I can install the generated eboot loader onto
the board through an application that came from Cirrus.
My problem is that under the target/connectivity options menu it does not
show any options for download/transport/debugger. It just has "None" in all
three boxes. I know I should get an option for ethernet in transport at
least along with some other options. What has gone wrong here? Is it
because this is the evaluation platform builder? I am running Visual Studio
2005 professional edition. Do I need to uninstall Active Sync perhaps? I've
already tried shutting it down and running multiple instances of VS2005.
There must be a setting I have missed somewhere.
Anyones help would be much appreciated.
Thank you
"alext@xxxxxxxxxxxxx" wrote:
I'm having lots of problems trying to connect to a CE 6.0 device using.
the remote tools like registry viewer. The device is connected via
Ethernet and debugging via Visual Studio 2005 works fine. I haven't
been able to resolve it, after doing/checking the following:
- made sure KITL enabled build setting is on and all the KITL settings
in the connectivity options are checked.
-Tried debug and release builds
- I am trying to use KITL Tranpsort as transport and CESH as startup
server - I get the error "Unable to load device side components. Please
check server configuration settings". These settings worked fine under
CE 5.0 platform builder (and still does).
- tried running both the CE 5.0 and CE 6.0 versions of the remote tools
directly by launching the .exe's without success.
- I have tried all other remote connection methods/combos
(KITL/CESH/MANUAL) without success.
What should I check I should have component-wise in my build to get
this working - as far as I can tell, my build has the same components
as my CE 5.0 version.
- Follow-Ups:
- Re: Windows CE 6.0 remote tools broken?
- From: Gary Swalling
- Re: Windows CE 6.0 remote tools broken?
- Prev by Date: Re: SQl Server 2005 Mobile and Platform Builder 5.0
- Next by Date: Re: RequestDeviceNotifications for WLAN card
- Previous by thread: RequestDeviceNotifications for WLAN card
- Next by thread: Re: Windows CE 6.0 remote tools broken?
- Index(es):
Relevant Pages
|