Re: Windows CE 6.0 remote tools broken?
- From: "Javier Grijalba" <Javier.Grijalba@xxxxxxxxxxxxxxxxxxxxxxxxx>
- Date: Wed, 29 Nov 2006 21:37:08 +0100
Hi ALex,
1)are you trying to connect without activesync like it is described here http://msdn2.microsoft.com/en-us/library/ms228708(VS.80).aspx ?
2)are you unsing the files
-Clientshutdown.exe
-ConmanClient2.exe
-CMaccept.exe
-eDbgTL.dll
-TcpConnectionA.dll
found here
C:\Program Files\Common Files\Microsoft Shared\CoreCon\1.0\Target\wce400\armv4i (depends of hardware)
3) or are you unsing the files
-Clientshutdown.exe
-ConmanClient2.exe
-tlkitlc.dll
found here
D:\Program Files\Windows CE Platform Builder\5.00\CORECON\TARGET\ARMV4I (depends of hardware)
Regards
Javier
On Mon, 27 Nov 2006 12:20:27 +0100, <alext@xxxxxxxxxxxxx> wrote:
Thanks for your reply Naveen.
Unfortunately I am not using Activesync so the Device Emulator Manager
doesn't behave the same way :(
Naveen wrote:Hi alext,
I am not sure whether this will work. but it worked fine for me...
Go to tools ... Click Device Emulator Manager.. Find out your device in
the list.. Connect to your device ( right click option).. IF device is
connected a green icon will be seen.. Now Right click and say cradle..
once this process finishes you will be able to see the remote reg
editor and use them.
Transport and start up server is both Microsoft Active Sync....
alext@xxxxxxxxxxxxx wrote:
> I'm having lots of problems trying to connect to a CE 6.0 device using
> the remote tools like registry viewer. The device is connected via
> Ethernet and debugging via Visual Studio 2005 works fine. I haven't
> been able to resolve it, after doing/checking the following:
>
> - made sure KITL enabled build setting is on and all the KITL settings
> in the connectivity options are checked.
>
> -Tried debug and release builds
>
> - I am trying to use KITL Tranpsort as transport and CESH as startup
> server - I get the error "Unable to load device side components. Please
> check server configuration settings". These settings worked fine under
> CE 5.0 platform builder (and still does).
>
> - tried running both the CE 5.0 and CE 6.0 versions of the remote tools
> directly by launching the .exe's without success.
>
> - I have tried all other remote connection methods/combos
> (KITL/CESH/MANUAL) without success.
>
> What should I check I should have component-wise in my build to get
> this working - as far as I can tell, my build has the same components
> as my CE 5.0 version.
--
Javier Grijalba
www.positivesystems.com
Touch Panel PC systems
JGrijalba at Positivesystems dot com
.