Re: Remote Tools not connecting



Can you check if platform manager is configured to use CESH + KITL

--
----------------------------------------------------------------
Yannick Chamming's (eMVP)
ADENEO (ADESET)
Windows Embedded Manager
ychammings AT adeset DOT com>
http://www.adeset.com
Tél : +33 (0)4.72.18.57.77
Fax : +33 (0)4.72.18.57.78
----------------------------------------------------------------

"Benoît Bousquet" <bbousquet@xxxxxxxxxxxxxxxx> a écrit dans le message de
news: %23h69iqRnFHA.1088@xxxxxxxxxxxxxxxxxxxxxxx
> Thanks for the reply, but that option was already enabled. Here's a list
> of my platform options (Platform/Settings/Build Options) for the debug
> build:
>
> - Enable CE Target Control Support
> - Enable Eboot Space in Memory
> - Enable Full Kernel Mode
> - Enable Images Larger than 32MB
> - Enable Kernel Debugger
> - Enable KITL
>
> As a side note, I have tried using the emulator instead of a target PC and
> it yields the same result (remote tools not working, although everything
> seems to). When I was messing around with the target PC I also realized
> that my crossover cable was useless - I just connected the CE machine to
> the main company network and it worked fine for downloading/debugging
> (still no remote tools however).
>
> -BB
>
> "Dean Ramsier" <ramsiernospam@xxxxxxxxxx> wrote in message
> news:uMQa8aRnFHA.3288@xxxxxxxxxxxxxxxxxxxxxxx
>> You need CE target control support in order to allow the remote tools to
>> work. Should be an option in Platform->Settings, or from the catalog at
>> Core Os->Kernel Features. Ends up resolving to SYSGEN_SHELL, and pulling
>> in
>> the relfsd component.
>>
>> --
>> Dean Ramsier - eMVP
>>
>>
>> "Benoît Bousquet" <bbousquet@xxxxxxxxxxxxxxxx> wrote in message
>> news:OXL7wfPnFHA.420@xxxxxxxxxxxxxxxxxxxxxxx
>>> Greetings.
>>>
>>> Using PB 4.2. Current setup:
>>> - development PC with 2 network cards (one to main company network, the
>>> other connected to target PC with a crossover cable, using address
>>> 192.168.10.1)
>>> - target PC with 1 network card (192.168.10.2 set on the boot floppy,
>>> connected to development PC with crossover cable)
>>>
>>> I built a pretty basic CEPC/Mobile Handheld image, have configured the
>>> PB
>>> remote connection as Ethernet for both Download and Kernel Transport,
>>> and
>> my
>>> target PC downloads and boots the image successfully - I also get a ton
>>> of
>>> traces, as it should be.
>>>
>>> So far, all is good. However, I can't seem to be able to connect to the
>>> target PC with ANY of the remote tools. I'm somewhat confused as to the
>>> steps required. I tried (I believe) all the combinations in the remote
>>> tools' connection panels, to no avail.
>>>
>>> I have a NULL cable (serial) lying around if it can actually help.
>>>
>>> --
>>> -----
>>> Benoît Bousquet
>>> (e-mail address is invalid)
>>>
>>>
>>
>>
>
>


.



Relevant Pages

  • Re: Remote Tools not connecting
    ... my platform options for the debug build: ... - Enable CE Target Control Support ... it yields the same result (remote tools not working, ... >> tools' connection panels, to no avail. ...
    (microsoft.public.windowsce.platbuilder)
  • Re: Connect VS 2005 to running platform without ActiveSync
    ... Are you sure that you set the target IP address in Device options in VS2005 ... Add the CoreCon functionality to the platform as a catalog component ... If target is an ActiveSync device, ... ActiveSync connection is running. ...
    (microsoft.public.windowsce.platbuilder)
  • Re: Using remote tools in eVC++ 4.0!
    ... Remote Tools, no, you don't need to enable the kernel debugger or target ... suitable remote tool and start it from eVC, check the Platform Manager ...
    (microsoft.public.windowsce.platbuilder)
  • Re: User Creation problem in AD
    ... is any connection with RID because im not able to create new ... SOA record data from server: ... Performing upstream analysis. ... Performing downstream (of target) analysis. ...
    (microsoft.public.windows.server.active_directory)
  • Re: Information on migration of DMS2200 to relational databases
    ... application infrastructure is available on the possible target ... DML for DMS 2200 access and currency are very important as the ... Make sure every function including paging support, line I/O, ... Staying on the existing platform is always an option, ...
    (comp.sys.unisys)