s3c2410x cpu miss Uart1 Interrupt???
- From: auronc@xxxxxxxxx
- Date: 28 May 2005 18:41:23 -0700
In OEMInterruptHandler(), I add some code to see Uart FIFO count.
I set my uart Rx-interrupt trigger level : 4 bytes.
In my expectation, the debug msg is:
Check Uart1 FIFO Count 4
Check Uart1 FIFO Count 4
Check Uart1 FIFO Count 4
.....
But sometime, the debug msg is:
Check Uart1 FIFO Count 15
......
It means the Overrun error, the FIFO is full.
Why?
The CPU miss Uart1 Interrupt?
or
OS call OEMInterruptHandler() too slowly?
Please give me a hand, thx for your suggestion.
[OEMInterruptHandler]
/////////////////////////////////////////////////////
else if(IntPendVal == INTSRC_UART1) // SERIAL
{
RETAILMSG(0, (TEXT("INT:SYSINTR_SERIAL INT\r\n")));
SubIntPendVal = s2410INT->rSUBSRCPND;
if(SubIntPendVal & INTSUB_ERR1)
{
s2410INT->rINTSUBMSK |= INTSUB_ERR1;
}
else if(SubIntPendVal & INTSUB_RXD1)
{
s2410INT->rINTSUBMSK |= INTSUB_RXD1;
//*****************************************************************
RETAILMSG(1, "Check Uart1 FIFO Count %d", (pUart1->rUFSTAT & 0xf) );
}
else if(SubIntPendVal & INTSUB_TXD1)
{
s2410INT->rINTSUBMSK |= INTSUB_TXD1;
}
else
return SYSINTR_NOP;
///////////////////////////////////////////////////////////
.
- Prev by Date: SDK Development problems
- Next by Date: SMSC 91C111 and PXA270
- Previous by thread: SDK Development problems
- Next by thread: SMSC 91C111 and PXA270