Re: Problems on ActiveSync on CE4.2 using UART
From: LL (lilian_at_nospam.bokia.net)
Date: 02/27/04
- Next message: Tweeeek: "Re: Bootloader.....Global variable Problem"
- Previous message: Thomas Buerkli: "Installable ISR"
- In reply to: Valter Minute: "Re: Problems on ActiveSync on CE4.2 using UART"
- Next in thread: Valter Minute: "Re: Problems on ActiveSync on CE4.2 using UART"
- Reply: Valter Minute: "Re: Problems on ActiveSync on CE4.2 using UART"
- Messages sorted by: [ date ] [ thread ]
Date: Fri, 27 Feb 2004 17:12:16 +0800
Thanks Valter. I will try what is the debug output on this.
Now I am able to get the ActiveSync to get connected whereby at MS
ActiveSync 3.7.1 is at "Connected" stage (The green round icon stops
rotating). At the device side, ActiveSync is at "Connected" stage as well.
After waiting for a very long time, I sometimes can get "Partnerships" and
sometimes fail to connect at all - "Fail partnerships" (The icon becomes
gray).
When I get the "Partnership" (which takes a very long time), I fail to enter
"Explore" in the device. MS ActiveSync seems to hanged. What is the cause
that the device fail to be "Explore"?
To me, it seems that both PC and device are not synchronized well. Can
anyone tell me, how to synchronize better? Or is it not the synchronizing
matter but other matters?
Thanks
Regards,
Lilian
"Valter Minute" <vminute@REMOVEMEinwind.it> wrote in message
news:Xns949C62B512DDAVALTERMINUTE@207.46.248.16...
> "LL" <lilian@nospam.bokia.net> wrote in
> news:e5SRLRN$DHA.2800@tk2msftngp13.phx.gbl:
>
> > Hi,
> >
> > I read from the newsgroup, and I found out that some could
> > implement ActiveSync by shorting pin 1-4-6 and connecting RX, TX,
> > CTS, RTS to both ends. I have did this, and could get the both
> > CLIENT and CLIENTSERVER (please refer to my previous posting).
> > After CLIENTSERVER, I get strange characters reading/writing from
> > the PC to the device and vice versa. Can I know what are these
> > characters ~.}#.!}"} } }.}"}&} } } } }'}"}(}"..~ .... ?
> [...]
> > Can anyone tell was is going wrong?
>
> Try to enable the ActiveSync (and unimodem) related debug zones (see
> registry entries at the end of message, I took them from one of my old
> projects, so it could contain wrong entries...) and check the debug
> output.
>
> [HKEY_LOCAL_MACHINE\DebugZones]
> "RLOG"=dword:ffff
> "repllog"=dword:ffff
> "rnaapp"=dword:ffff
> "Repllog.exe - Change Log Agent"=dword:ffff
> "Unimodem"=dword:ffff
>
>
> --
> Valter Minute
> vminute@inwind.it (the reply address of this message is invalid)
- Next message: Tweeeek: "Re: Bootloader.....Global variable Problem"
- Previous message: Thomas Buerkli: "Installable ISR"
- In reply to: Valter Minute: "Re: Problems on ActiveSync on CE4.2 using UART"
- Next in thread: Valter Minute: "Re: Problems on ActiveSync on CE4.2 using UART"
- Reply: Valter Minute: "Re: Problems on ActiveSync on CE4.2 using UART"
- Messages sorted by: [ date ] [ thread ]
Relevant Pages
|
|