Re: CE 5.0 unable to read settings from the datastore
- From: "Luca Calligaris" <anonymous@xxxxxxxxxxxxxxxxxxxxxxxxx>
- Date: Thu, 24 Apr 2008 14:21:31 +0200
you should find a folder named ...\Windows CE Platform
Builder\5.00\CORECON\SCRIPTS.
try to run the batch files inside in this order:
disablecorecon
unregister
register
enablecorecon
all of them need as an argument the full path to ...\Windows CE Platform
Builder\5.00
--
Luca Calligaris
www.eurotech.it
"mike 1369" <mike 1369@xxxxxxxxxxxxxxxxxxxxxxxxx> ha scritto nel messaggio
news:912EDFAD-A580-4B2A-9487-4EEA5CE27F03@xxxxxxxxxxxxxxxx
Hello all,
After a short evaluation of Windows CE 6.0, I finally had to install CE
5.0,
as the platform I could use had CE 5.0.
So I uninstalled CE 6.0 and Visual C 2005 Pro, then installed WinCE 5.0.
Here is my problem: the menu [Target] / [Connectivity Options] gives the
following error : "platform builder was unable to read the device settings
from the datastore"
I saw this note on the web :
http://blogs.msdn.com/dcook/archive/2007/05/13/does-pb-5-0-work-side-by-side-with-pb-6-0.aspx
but I have no "CoreCon" in my settings
Something is corrupted somewhere, but I can't find it
Thanks for your help
.
- Follow-Ups:
- Re: CE 5.0 unable to read settings from the datastore
- From: mike 1369
- Re: CE 5.0 unable to read settings from the datastore
- References:
- CE 5.0 unable to read settings from the datastore
- From: mike 1369
- CE 5.0 unable to read settings from the datastore
- Prev by Date: Problem with datagrid
- Next by Date: Re: CE 5.0 unable to read settings from the datastore
- Previous by thread: CE 5.0 unable to read settings from the datastore
- Next by thread: Re: CE 5.0 unable to read settings from the datastore
- Index(es):
Relevant Pages
|
|