Re: CE 5.0 unable to read settings from the datastore



you should find a folder named ...\Windows CE Platform
Builder\5.00\CORECON\SCRIPTS.
try to run the batch files inside in this order:

disablecorecon
unregister
register
enablecorecon

all of them need as an argument the full path to ...\Windows CE Platform
Builder\5.00

--

Luca Calligaris
www.eurotech.it

"mike 1369" <mike 1369@xxxxxxxxxxxxxxxxxxxxxxxxx> ha scritto nel messaggio
news:912EDFAD-A580-4B2A-9487-4EEA5CE27F03@xxxxxxxxxxxxxxxx
Hello all,

After a short evaluation of Windows CE 6.0, I finally had to install CE
5.0,
as the platform I could use had CE 5.0.
So I uninstalled CE 6.0 and Visual C 2005 Pro, then installed WinCE 5.0.

Here is my problem: the menu [Target] / [Connectivity Options] gives the
following error : "platform builder was unable to read the device settings
from the datastore"

I saw this note on the web :
http://blogs.msdn.com/dcook/archive/2007/05/13/does-pb-5-0-work-side-by-side-with-pb-6-0.aspx
but I have no "CoreCon" in my settings

Something is corrupted somewhere, but I can't find it

Thanks for your help



.



Relevant Pages

  • Re: CE 5.0 unable to read settings from the datastore
    ... "Luca Calligaris" wrote: ... as the platform I could use had CE 5.0. ... So I uninstalled CE 6.0 and Visual C 2005 Pro, then installed WinCE 5.0. ... "platform builder was unable to read the device settings ...
    (microsoft.public.windowsce.embedded)
  • CE 5.0 unable to read settings from the datastore
    ... After a short evaluation of Windows CE 6.0, I finally had to install CE 5.0, ... as the platform I could use had CE 5.0. ... "platform builder was unable to read the device settings ...
    (microsoft.public.windowsce.embedded)