Re: Activesync problem connecting to CEPC downloaded image



Thanks Paul, but i have already some problem.
I wil try to explain situation better:
i use a CEPC with 2 serial port (3F8/IRQ4 and 2F8/IRQ3).
If i connect the com1 with hiperterminal during boot of image i can see
debug message. When image is loaded i put the cable on the other serial port
(com1 for the image but com2 of the pc), create a new connection onto cepc
for com1, start repllog and i can see in hyperterminal the string CONNECT.
Finally i stop Hyperterminal and try to connect with activesync. On my pc
after a while i have the green icon and sayd CONNECTED (guest). At this point
no syncronize windows appears (but with emulator it appears). The two pc
seems connected but i try to explore files, only an empty folder appears.
I have tried to use some remote tool on PB 5, but the test for the default
connection for some combination of Transport and Service always failed.

You said: " I just get the feeling that you haven't followed the required
steps. I've covered setting this up for serial connection before. "
I searched where you told me, and i find o lot of thing, but i'm not sure
what are the required step to take. Can You help me a little?
Thanks again.

"Paul G. Tobey [eMVP]" wrote:

> The easiest way is to verify that your board support package sends the debug
> messages somewhere else or nowhere at all.
>
> Did you go through the steps of setting up a connectoid for the AS
> connection? I just get the feeling that you haven't followed the required
> steps. I've covered setting this up for serial connection before. At a
> guess, it was probably in microsoft.public.windowsce.platbuilder. You can
> search using GoogleGroups (you might search microsoft.public.windowsce.* to
> cover all the groups I normally read).
>
> Paul T.
>
> "Roberto" <Roberto@xxxxxxxxxxxxxxxxxxxxxxxxx> wrote in message
> news:86A12130-667D-4FC0-B830-75B2C7FA8E20@xxxxxxxxxxxxxxxx
> >I have tried to download an image into emulator and connect to it, and
> > everything works perfectly (with activesync 4.1). But the problem persist
> > onto cepc image.
> > The com port is used only by activesync. What about serial debug? Haw can
> > i
> > verify that no debug message are sent to that port?
> >
> > "Paul G. Tobey [eMVP]" wrote:
> >
> >> I'm not sure what's wrong, but you should make sure that all of the
> >> ActiveSync components are included in your OS, verify that no other
> >> process
> >> besides repllog.exe is trying to use the serial port (make sure, for
> >> example, that you aren't trying to send serial debug output to that
> >> port),
> >> and use AS 3.8.
> >>
> >> Paul T.
> >>
> >> "Roberto" <Roberto@xxxxxxxxxxxxxxxxxxxxxxxxx> wrote in message
> >> news:6B3D0DA5-D340-47FC-B377-8C85CB29F84F@xxxxxxxxxxxxxxxx
> >> >I want to add something...
> >> > I have tried with ActiveSync 3.8, 4.0 and 4.1
> >> > The same thing for all three.
> >> >
> >> > Any suggestion?
> >> >
> >> > "Roberto" wrote:
> >> >
> >> >> Hi everybody, i'm new!!
> >> >> I'm doing some experiments on Platform Builder 5 (the first time).
> >> >> I have done a custom image for CEPC, downloaded onto a pc with
> >> >> network. I
> >> >> put the image onto HD and now it boots from the hard drive. Then i
> >> >> tried
> >> >> to
> >> >> connect to my pc with activesync (serial cable). The connection seems
> >> >> to
> >> >> be
> >> >> done (it's green on my desktop and in the CEPC it is connected), but
> >> >> if i
> >> >> try
> >> >> to Explore the files, i cannot see anything. Even trying a "remote
> >> >> connection" from Platform Builder -> Tools. Can someone explain it to
> >> >> me?
> >> >> What's wrong?
> >> >> Thanks all and sorry for my english! :-)
> >>
> >>
> >>
>
>
>
.



Relevant Pages

  • Re: OpenSSH 3.4p1 port forwarding problem
    ... > I am attempting to setup port forwarding of port 1680 over the SSH ... The connection has been closed." ... > debug: Entering interactive session. ...
    (comp.unix.sco.misc)
  • Re: OPA0 Console connection
    ... COM1 and COM2 don't always map the same ... :disables login from that port, so that is not the right approach. ... and which will receive the connection. ...
    (comp.os.vms)
  • Re: AciveSync serial connection problems
    ... It turns out that the COM port hardware on my CE device was inverting the ... I checked that ActiveSync was working in 5.0 with a CEPC. ... COM4 is not the debug com port, ... I configured ActiveSync to use my connectoid via the PC Connection ...
    (microsoft.public.windowsce.platbuilder)
  • Re: Using VT420 as Alpha System Console
    ... :port 1 - the right-hand one. ... COM1 is the console serial port when the CONSOLE environment ... Com1 is the upper PC-style DB9 connection, ...
    (comp.os.vms)
  • Re: Serial COM1 on Cerfboard 255 PXA 250
    ... I am having a problem in opening the serial port COM1 on the Cerfboard 255, ... According to the documentation, I could disable the debug feature by switching the SW3-2 OFF, therefore freeing the serial port COM1 for user. ...
    (microsoft.public.windowsce.platbuilder)