Re: W32Time Problems
- From: w32time <w32time@xxxxxxxxxxxxxxxxxxxxxxxxx>
- Date: Tue, 21 Apr 2009 01:26:03 -0700
I have setup two domain controllers in a test environment to test this
solution.
I am still receiving the same errors. The domain controller that has the PDC
Emulator role in DomainSRV1. See below events.
DomainSRV20 11:42am 20/04/09 ran command "w32tm /config /update
/manualpeerlist:"DomainSRV1.internal.testdomain.com" /syncfromflags:MANUAL
/reliable:YES"
DomainSRV20 11:42am 20/04/09 ran command "net stop w32time && net start
w32time"
DomainSRV20 11:43:17am 20/04/09
Event Type: Information
Event Source: W32Time
Event Category: None
Event ID: 35
Date: 4/20/2009
Time: 11:43:30 AM
User: N/A
Computer: DomainSRV20
Description:
The time service is now synchronizing the system time with the time source
DomainSRV1.internal.testdomain.com
(ntp.m|0x0|169.254.10.60:123->169.254.10.10:123).
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
DomainSRV1 11:56am 20/04/09 rebooted server DomainSRV1
Event Type: Information
Event Source: W32Time
Event Category: None
Event ID: 38
Date: 4/20/2009
Time: 11:57:12 AM
User: N/A
Computer: DomainSRV20
Description:
The time provider NtpClient cannot reach or is currently receiving invalid
time data from DomainSRV1.internal.testdomain.com
(ntp.m|0x0|169.254.10.60:123->169.254.10.10:123).
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Event Type: Information
Event Source: W32Time
Event Category: None
Event ID: 38
Date: 4/20/2009
Time: 11:57:12 AM
User: N/A
Computer: DomainSRV20
Description:
The time provider NtpClient cannot reach or is currently receiving invalid
time data from DomainSRV1.internal.testdomain.com
(ntp.m|0x0|169.254.10.60:123->169.254.10.10:123).
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 50
Date: 4/21/2009
Time: 6:15:42 AM
User: N/A
Computer: DomainSRV20
Description:
The time service detected a time difference of greater than 5000
milliseconds for 900 seconds. The time difference might be caused by
synchronization with low-accuracy time sources or by suboptimal network
conditions. The time service is no longer synchronized and cannot provide the
time to other clients or update the system clock. When a valid time stamp is
received from a time service provider, the time service will correct itself.
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
DomainSRV20 9:57am 21/04/09 ran command "w32tm /config /syncfromflags:domhier"
DomainSRV20 9:57am 21/04/09 ran command "net stop w32time && net start
w32time"
Event Type: Information
Event Source: W32Time
Event Category: None
Event ID: 37
Date: 4/21/2009
Time: 9:57:17 AM
User: N/A
Computer: DomainSRV20
Description:
The time provider NtpClient is currently receiving valid time data from
DomainSRV1.internal.testdomain.com
(ntp.m|0x0|169.254.10.60:123->169.254.10.10:123).
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
DomainSRV1 10:47am 21/04/09 shutdown server DomainSRV1
DomainSRV20 10:51:51am
Event Type: Information
Event Source: W32Time
Event Category: None
Event ID: 38
Date: 4/21/2009
Time: 10:51:51 AM
User: N/A
Computer: DomainSRV20
Description:
The time provider NtpClient cannot reach or is currently receiving invalid
time data from DomainSRV1.internal.testdomain.com
(ntp.m|0x0|169.254.10.60:123->169.254.10.10:123).
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 47
Date: 4/21/2009
Time: 10:56:40 AM
User: N/A
Computer: DomainSRV20
Description:
Time Provider NtpClient: No valid response has been received from manually
configured peer DomainSRV1.internal.testdomain.com after 8 attempts to
contact it. This peer will be discarded as a time source and NtpClient will
attempt to discover a new peer with this DNS name.
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Event Type: Error
Event Source: W32Time
Event Category: None
Event ID: 29
Date: 4/21/2009
Time: 10:56:40 AM
User: N/A
Computer: DomainSRV20
Description:
The time provider NtpClient is configured to acquire time from one or more
time sources, however none of the sources are currently accessible. No
attempt to contact a source will be made for 15 minutes. NtpClient has no
source of accurate time.
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Event Type: Information
Event Source: W32Time
Event Category: None
Event ID: 38
Date: 4/21/2009
Time: 10:51:51 AM
User: N/A
Computer: DomainSRV20
Description:
The time provider NtpClient cannot reach or is currently receiving invalid
time data from DomainSRV1.internal.testdomain.com
(ntp.m|0x0|169.254.10.60:123->169.254.10.10:123).
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 47
Date: 4/21/2009
Time: 10:56:40 AM
User: N/A
Computer: DomainSRV20
Description:
Time Provider NtpClient: No valid response has been received from manually
configured peer DomainSRV1.internal.testdomain.com after 8 attempts to
contact it. This peer will be discarded as a time source and NtpClient will
attempt to discover a new peer with this DNS name.
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Event Type: Error
Event Source: W32Time
Event Category: None
Event ID: 29
Date: 4/21/2009
Time: 10:56:40 AM
User: N/A
Computer: DomainSRV20
Description:
The time provider NtpClient is configured to acquire time from one or more
time sources, however none of the sources are currently accessible. No
attempt to contact a source will be made for 15 minutes. NtpClient has no
source of accurate time.
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
DomainSRV1 10:58:30am 21/04/09 started server DomainSRV1
DomainSRV20 11:11:42am 21/04/09
Event Type: Information
Event Source: W32Time
Event Category: None
Event ID: 37
Date: 4/21/2009
Time: 11:11:42 AM
User: N/A
Computer: DomainSRV20
Description:
The time provider NtpClient is currently receiving valid time data from
DomainSRV1.internal.testdomain.com
(ntp.m|0x0|169.254.10.60:123->169.254.10.10:123).
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
DomainSRV1 11:18am 21/04/09 shutdown server DomainSRV1
DomainSRV20 10:28:38am 21/04/09
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 50
Date: 4/21/2009
Time: 11:28:38 AM
User: N/A
Computer: DomainSRV20
Description:
The time service detected a time difference of greater than 5000
milliseconds for 900 seconds. The time difference might be caused by
synchronization with low-accuracy time sources or by suboptimal network
conditions. The time service is no longer synchronized and cannot provide the
time to other clients or update the system clock. When a valid time stamp is
received from a time service provider, the time service will correct itself.
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
DomainSRV20 11:28:38am 21/04/09
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 50
Date: 4/21/2009
Time: 11:28:38 AM
User: N/A
Computer: DomainSRV20
Description:
The time service detected a time difference of greater than 5000
milliseconds for 900 seconds. The time difference might be caused by
synchronization with low-accuracy time sources or by suboptimal network
conditions. The time service is no longer synchronized and cannot provide the
time to other clients or update the system clock. When a valid time stamp is
received from a time service provider, the time service will correct itself.
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
DomainSRV20 3:43:37am 21/04/09
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 50
Date: 4/21/2009
Time: 11:28:38 AM
User: N/A
Computer: DomainSRV20
Description:
The time service detected a time difference of greater than 5000
milliseconds for 900 seconds. The time difference might be caused by
synchronization with low-accuracy time sources or by suboptimal network
conditions. The time service is no longer synchronized and cannot provide the
time to other clients or update the system clock. When a valid time stamp is
received from a time service provider, the time service will correct itself.
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 50
Date: 4/21/2009
Time: 3:43:37 PM
User: N/A
Computer: DomainSRV20
Description:
The time service detected a time difference of greater than 5000
milliseconds for 900 seconds. The time difference might be caused by
synchronization with low-accuracy time sources or by suboptimal network
conditions. The time service is no longer synchronized and cannot provide the
time to other clients or update the system clock. When a valid time stamp is
received from a time service provider, the time service will correct itself.
For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
.
- Follow-Ups:
- Re: W32Time Problems
- From: Meinolf Weber [MVP-DS]
- Re: W32Time Problems
- References:
- W32Time Problems
- From: w32time
- Re: W32Time Problems
- From: Meinolf Weber [MVP-DS]
- Re: W32Time Problems
- From: w32time
- Re: W32Time Problems
- From: Meinolf Weber [MVP-DS]
- W32Time Problems
- Prev by Date: Re: winnt32 /cmdcons error: Setup cannot run in program compatibility
- Next by Date: Re: W32Time Problems
- Previous by thread: Re: W32Time Problems
- Next by thread: Re: W32Time Problems
- Index(es):
Relevant Pages
|