Re: ADS Sysprep [SysprepMassStorage] problem with Compaq.

From: Mark (mark.miller_at_zurichna.invalid)
Date: 05/11/04


Date: Tue, 11 May 2004 08:49:58 -0500

I have struggled with the same issues the your are currently experiencing.
Here is a solution I found that works with Windows Server 2003

1) Go to
http://h18023.www1.hp.com/support/files/server/us/download/20313.html
    and download the softpaq
2) Extract the drivers to a folder of your choice.
3) Copy ONLY the "CpqCissm.sys" file from the folder that you extracted the
drivers to.
4) Paste the above file to c:\%windir%\system32\drivers on your Master
Device
5) Capture the image

** Since you already have an image created, you might just try mounting your
image and adding the driver in that way before you redeploy it.

You should now be able to have a more portable image. The driver you copied
encompasses the following controllers:
Smart Array 5300 Controller
Smart Array 5i
Smart Array 532 Controller
Smart Array 5312 Controller
Smart Array 641 Controller
Smart Array 642 Controller
Smart Array 6400 Controller
Smart Array 6400 U320 EM Controller

I use an old IBM Netfinity server as my Master Device and was able to follow
the steps above and deploy an image on an HP ML530 with no problems. Again,
I was using Windows Server 2003, but I would assume that it would work under
windows 2000 as well.

If not, you might want to look at rebuilding your image and using F6 to add
in the storage controller drivers this way. Now they will be a part of the
image you are capturing.

Mark

"Lloyd" <lloyd.carnie@bp.com> wrote in message
news:39E6D18D-B03D-4FC4-A090-4053F3AECE23@microsoft.com...
> Help!!
>
> I have a base Win2K image captured with a Smart 5i controller and I need
to deploy to servers with 5312 and 6400 controllers. I have tried loads of
different variations in my Sysprep.inf but the server always blue screens
with Inaccessible_boot_device.
>
> Here is a sample:
>
> ;SetupMgrTag
> [Unattended]
> OemPreInstall = Yes
> OemSkipEula=Yes
> InstallFilesPath=C:\sysprep\i386
> OemPnPDriversPath = "drivers"
>
> [SysprepMassStorage]
> PCI\VEN_0E11&DEV_B060 = "C:\Drivers\Storage\cpqcissm.inf", "\", "Smart
Array 5x and 6x Driver Diskette", "\TXTSETUP.OEM"
> PCI\VEN_0E11&DEV_B178 = "C:\Drivers\Storage\cpqcissm.inf", "\", "Smart
Array 5x and 6x Driver Diskette", "\TXTSETUP.OEM"
> PCI\VEN_0E11&DEV_0046 = "C:\Drivers\Storage\cpqcissm.inf", "\", "Smart
Array 5x and 6x Driver Diskette", "\TXTSETUP.OEM"
>
> Can anyone help me with an example of a Sysprep with Compaq server options
filled in and the correct location of files?
>
> Many thank
>
> Lloyd
>
>



Relevant Pages

  • Re: USBIP protocol
    ... 'Client' and 'Server' are totally not clear. ... machine in the closet without USB devices, or is the machine with the ... The controller machine now gets a device 9-2 which accesses the target ... client and hci-hcd is a host controller driver on the server. ...
    (Linux-Kernel)
  • Re: BartPE and Smart Arrary 6i driver
    ... > with a 300GB hard drive using HP Smart Array 6i controller. ... > see the hard drive because it does not have the 6i driver. ... > Since this server does not have a floopy disk, ...
    (comp.sys.ibm.pc.hardware.storage)
  • Re: ADS Sysprep [SysprepMassStorage] problem with Compaq.
    ... I have a solution that works for Server 2003, but since you are running W2K, ... your array controller drivers for your Master ... Smart Array 5300 Controller ...
    (microsoft.public.windows.server.setup)
  • Disk errors... This one is Odd.... Please help
    ... I have a Windows 2003 server running on a highend DEll ... controller. ... when I see and error "The driver detected a controller ... the XP driver AND the beta 2003 ...
    (microsoft.public.windows.file_system)
  • BartPE and Smart Arrary 6i driver
    ... Trying to boot up the system in Bart-PE but the later cannot ... Since this server does not have a floopy disk, ... How can I let Bart-PE to recognize the Smart Array 6i controller ...
    (comp.sys.ibm.pc.hardware.storage)