Re: Time Sync Issue on DC's
- From: Meinolf Weber <meiweb(nospam)@gmx.de>
- Date: Thu, 3 Apr 2008 05:50:07 +0000 (UTC)
Hello Harleyd,
Configure the PDCEmulator to sync with an external time source and reconfigure the other machines to use only domain time.
PDCEmulator:
w32tm /config /manualpeerlist:peers /syncfromflags:manual /reliable:yes /update
With "peers" you can set the time source, either DNS name (time.windows.com) or an ip address from a reliable time source.
Here you can find some of them:
http://www.pool.ntp.org/
All other machines:
To configure a client computer for automatic domain time synchronization
1. Open a Command Prompt.
2. Type the following command and then press ENTER:
w32tm /config /syncfromflags:domhier /update
3. Type the following command and then press ENTER:
net stop w32time
4. Type the following command and then press ENTER:
net start w32time
Best regards
Meinolf Weber
Disclaimer: This posting is provided "AS IS" with no warranties, and confers no rights.
** Please do NOT email, only reply to Newsgroups
** HELP us help YOU!!! http://www.blakjak.demon.co.uk/mul_crss.htm
So I have inherited a new location which I am finding some problems
with. I am receiving continuous errors in the event log related to
time synchronization on our eight 2003 SP2 Domain Controllers. Here is
what I am getting on my PDC:
Event Type: Error
Event Source: W32Time
Event Category: None
Event ID: 29
Date: 4/1/2008
Time: 11:49:28 AM
User: N/A
Computer: FDC-P02
Description:
The time provider NtpClient is configured to acquire time from one or
more
time sources, however none of the sources are currently accessible.
No
attempt to contact a source will be made for 120 minutes. NtpClient
has no
source of accurate time.
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 47
Date: 4/1/2008
Time: 11:49:28 AM
User: N/A
Computer: FDC-P02
Description:
Time Provider NtpClient: No valid response has been received from
manually
configured peer time.windows.com,0x1 after 8 attempts to contact it.
This
peer will be discarded as a time source and NtpClient will attempt to
discover a new peer with this DNS name.
Event Type: Information
Event Source: W32Time
Event Category: None
Event ID: 38
Date: 4/1/2008
Time: 6:49:28 AM
User: N/A
Computer: FDC-P02
Description:
The time provider NtpClient cannot reach or is currently receiving
invalid
time data from time.windows.com
(ntp.m|0x1|10.XXX.XX.XXX:123->207.XX.XXX.XX:123).
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 36
Date: 4/1/2008
Time: 6:04:28 AM
User: N/A
Computer: FDC-P02
Description:
The time service has not synchronized the system time for 86400
seconds
because none of the time service providers provided a usable time
stamp. The
time service is no longer synchronized and cannot provide the time to
other
clients or update the system clock. Monitor the system events
displayed in
the Event Viewer to make sure that a more serious problem does not
exist.
Event Type: Error
Event Source: W32Time
Event Category: None
Event ID: 29
Date: 4/1/2008
Time: 3:49:28 AM
User: N/A
Computer: FDC-P02
Description:
The time provider NtpClient is configured to acquire time from one or
more
time sources, however none of the sources are currently accessible.
No
attempt to contact a source will be made for 60 minutes. NtpClient has
no
source of accurate time.
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 47
Date: 4/1/2008
Time: 3:49:28 AM
User: N/A
Computer: FDC-P02
Description:
Time Provider NtpClient: No valid response has been received from
manually
configured peer time.windows.com,0x1 after 8 attempts to contact it.
This
peer will be discarded as a time source and NtpClient will attempt to
discover a new peer with this DNS name.
Event Type: Warning
Event Source: W32Time
Event Category: None
Event ID: 22
Date: 3/31/2008
Time: 6:00:37 AM
User: N/A
Computer: FDC-P02
Description:
The time provider NtpServer encountered an error while digitally
signing the
NTP response for peer 10.X.XXX.XX:123. NtpServer cannot provide
secure
(signed) time to the client and will ignore the request. The error
was: Not
enough storage is available to process this command. (0x80070008)
On FDC-P03 time /querysntp shows it configured to Tock.usno.navy.mil,
Net
time shows it pointing to another DC, FDC-P4
Note that Tock.usno.navy.mil seems to be restricted to just military
and gov.
On my PDC, FDC-P02 SNTP Query shows it configured to Time.windows.com,
Net
time shows it pointing to another DC, FDC-P4
On FDC-P04 through FDC-P08 SNTP Query shows it configured to
Time.windows.com, Net time shows it pointing to another DC, FDC-P4
FDC-P01 has the Schema and Domain Naming roles
FDC-P02 has the PDC, RID and Infrastructure roles
Thanks!
.
- References:
- Time Sync Issue on DC's
- From: Harleyd
- Time Sync Issue on DC's
- Prev by Date: MPS on Windows Server 2003 R2 SP2
- Next by Date: MS 312362 - The server was unable to allocate from the system pag
- Previous by thread: Time Sync Issue on DC's
- Next by thread: Processes not allocating properly memory
- Index(es):