Re: Error message question: The physical disk cannot...

From: Gerald Aigenbauer (ga_at_ntc.at)
Date: 02/17/05


Date: Thu, 17 Feb 2005 11:24:30 +0100

hi missoula!

itīs a hardware issue. you need to storage busses in each cluster node, one
for the internal disks and one for the shared disks.

gerald aigenbauer.

<missoula@gmail.com> schrieb im Newsbeitrag
news:1108605862.915476.208710@o13g2000cwo.googlegroups.com...
>I received the following message today when configuring Cluster
> Services:
>
> The physical disk "Disk C:" cannot be managed because it is on the same
> storage bus as the boot disk.
>
> Questions:
> 1) Is this a hardware issue that can only be resolved by new hardware
> (another storage bus)?
> 2) What exactly does this mean? If I install sQL Server on C:, will it
> not work with the cluster?
>
> This is a whole new world to me, so any help would be much appreciated.
> I'm using HP Proliant DL 380 servers.
>
> Thank you,
> -CJ
>



Relevant Pages

  • Re: Active/Passive Node Cluster DR Resources
    ... Loss of single node & restore from backup to same hardware ... Once we had the failed Node working we'd rejoin the cluster. ... Before we did that however we'd ensure that the Shared storage was ...
    (microsoft.public.windows.server.clustering)
  • Re: volume shadowing over LAVC ?
    ... It is when the crashed node that comes back on line and wants to re-integrate its disks that the rebuilding has to take place. ... hardware RAID and believe me, ... Hardware shadowing that is totally separate of VMS can be dangerous depending on configuration with regards to cluster partitioning. ...
    (comp.os.vms)
  • Re: With Scenario is the best and why? For a Windows 2003 file server Cluster
    ... as separate "disks". ... You'll have better performance from the storage ... MVP - Windows Server - Clustering ... Cluster: The Quorum is already configured and runnig. ...
    (microsoft.public.windows.server.clustering)
  • Re: Volume shadowing between FC Storage at different sites, and the allocation class
    ... I have done multiple tests on these disks across a multi-site cluster. ... I was able to shadow $1$DGA disks with Storageworks $2$DUA ... > I have just connected to some Fibrechannel based storage from my VMS ...
    (comp.os.vms)
  • Re: Blue Screen on 2 nodes - Please Help
    ... The Disks are what are known as VDisks - they are created on a HP EVA 5000 ... With regards to the resources taking 5mins, it does seem excessive, ... Either a bad driver or hardware is always the cause. ... is, the cluster has not been right for sometime, and I am unable to narrow ...