Re: clustering win2k3 enterprise problem.

Tech-Archive recommends: Repair Windows Errors & Optimize Windows Performance

From: arvid (arvid_at_inpact.nl)
Date: 10/11/04


Date: 11 Oct 2004 11:58:16 -0700

Found the solution for one node: a firmware upgrade did the trick!!

Greetz Arvid

"Mike Rosado [MSFT]" <mikeros@online.microsoft.com> wrote in message news:<416943ed@news.microsoft.com>...
> Arvid,
>
> It sounds like both your local drives and shared storage drive are using the
> same SCSI or Fibre controllers or are on the same bus. If they are two
> totally different controllers, then my questions would be:
>
> Was this an installation using the original media CD?
> Was it and installation using RiPrep?
> Was it and installation using RIS?
>
> From your original posting it sounds like you are indeed using two
> controllers, but they each need to be on separate bus. If you need further
> assistance configuring them to be on separate buses, then you may need to
> contact HP Technical Support.
>
> 309186 How the Cluster Service Takes Ownership of a Disk on the Shared Bus
> <http://support.microsoft.com/?id=309186>
>
> --
> Hope this helps,
> Mike Rosado
> Windows 2000 MCSE + MCDBA
> Microsoft Enterprise Platform Support
> Windows NT/2000/2003 Cluster Technologies
>
> ====================================================
> When responding to posts, please "Reply to Group" via your newsreader so
> that others may learn and benefit from your issue.
> ====================================================
>
> This posting is provided "AS IS" with no warranties, and confers no rights.
> <http://www.microsoft.com/info/cpyright.htm>
>
> -----Original Message-----
>
> "arvid" <arvid@inpact.nl> wrote in message
> news:37965645.0410092350.3f5fb115@posting.google.com...
> > Hi Mike,
> >
> > The configuration on the shared disk ( MSA) is exectly the same as
> > discribed in the article. I have 2 partiotions , one for quorum and
> > one for data, on the RAID 5 SCSI disks which are accesable from both
> > nodes.
> >
> > The part below from the log concerns me the most:
> > 2004-10-04 21:02:10.109 [INFO] xcl1: The physical disk "Disk D:"
> > cannot be managed because it is on the same storage bus as the boot
> > disk. (hr=00000000, {13E84779-125E-4B76-8C0D-1F5DB92EFE0F},
> > {1EFA8906-A36E-43BF-AF65-7F74413672EE}, 1, 1, 1), The cluster cannot
> > manage physical disks that are on the same storage bus as the volume
> > that contains the operating system because other nodes connected to
> > the storage bus cannot distinguish between these volumes and volumes
> > used for data.
> >
> > So it looks like that the solution lies within the re-assigning of the
> > bus location which are used bij both Raid controllers. Do you have any
> > idea how i can acomplish that?
> >
> > greetz Arvid
> >
> >
> > "Mike Rosado [MSFT]" <mikeros@online.microsoft.com> wrote in message
> news:<416742a9$1@news.microsoft.com>...
> > > Hi Arvid,
> > >
> > > You are probably correct in assuming "it appears that the problem is
> that
> > > the clustering service cannot find the quorum disk". Have you seen the
> > > following article?
> > >
> > > 280345 Quorum Drive Configuration Information
> > > http://support.microsoft.com/?id=280345
> > >
> > > --
> > > Hope this helps,
> > > Mike Rosado
> > > Windows 2000 MCSE + MCDBA
> > > Microsoft Enterprise Platform Support
> > > Windows NT/2000/2003 Cluster Technologies
> > >
> > > ====================================================
> > > When responding to posts, please "Reply to Group" via your newsreader so
> > > that others may learn and benefit from your issue.
> > > ====================================================
> > >
> > > This posting is provided "AS IS" with no warranties, and confers no
> rights.
> > > <http://www.microsoft.com/info/cpyright.htm>
> > >
> > > -----Original Message-----
> > >
> > > "arvid" <arvid@inpact.nl> wrote in message
> > > news:37965645.0410080710.2f3d94f7@posting.google.com...
> > > > HI,
> > > >
> > > > I'm trying to setup clustering on win2k3 enterprise edition. We have 2
> > > > Proliant dl380 servers and a Modular Smart Array used as a shared
> > > > disk. The proliant servers both have 2 scsi disks configured as raid
> > > > 1. The MSA has 3 scsi disks configured as raid 5. The MSA has 2 basic
> > > > partitions, one for Data(d:) and one for quorum ( e: , size 100mb)
> > > >
> > > > When i want to configure clustering for both nodes the log shows some
> > > > errors. It seems that the cluster setup fails because the OS (MBR)
> > > > share the same bus as the quorum which is needed by the clustering.
> > > > Here a part of the logfile:
> > > >
> > > > 1.Could not locate a sharable quorum resource and a local quorum
> > > > cluster will be created.
> > > > The quorum disk could not be located by the cluster service.
> > > >
> > > > 2004-10-04 21:02:06.031 [INFO] [MT] Connection to 'SQL-XCL' with
> > > > binding string '213.169.237.217' failed because the RPC is not
> > > > 2004-10-04 21:02:09.296 [INFO] xcl1: Found SCSI disk
> > > > '\\.\PHYSICALDRIVE1' on Bus '4' and Port '2'; at TID '1' and LUN '0'
> > > > (hr=00000000, {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:09.375 [INFO] xcl1: Physical disk PHYSICALDRIVE1 has
> > > > signature 67c2a58. (hr=00000000,
> > > > {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:09.546 [INFO] xcl1: Found physical disk
> > > > "\\.\PHYSICALDRIVE1" with partition "Disk #1, Partition #0" which has
> > > > the logical disk "D:". (hr=00000000,
> > > > {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:09.609 [INFO] [SRV] The disks on SCSI port 2 are
> > > > cluster capable.
> > > > 2004-10-04 21:02:09.656 [INFO] xcl1: Found SCSI disk
> > > > '\\.\PHYSICALDRIVE0' on Bus '4' and Port '2'; at TID '0' and LUN '0'
> > > > (hr=00000000, {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:09.703 [INFO] xcl1: Physical disk PHYSICALDRIVE0 has
> > > > signature 704c704c. (hr=00000000,
> > > > {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:09.859 [INFO] xcl1: Found physical disk
> > > > "\\.\PHYSICALDRIVE0" with partition "Disk #0, Partition #0" which has
> > > > the logical disk "C:". (hr=00000000,
> > > > {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:09.906 [INFO] [SRV] The disks on SCSI port 2 are
> > > > cluster capable.
> > > > 2004-10-04 21:02:09.953 [INFO] xcl1: Looking for disks on the same
> > > > storage bus as the boot disk... (hr=00000000,
> > > > {036BF567-2377-4BB3-8AE1-E4104E2EB3C5},
> > > > {13E84779-125E-4B76-8C0D-1F5DB92EFE0F}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:10.000 [INFO] xcl1: Looking for disks on the same
> > > > storage bus as the boot disk... (hr=00000000,
> > > > {036BF567-2377-4BB3-8AE1-E4104E2EB3C5},
> > > > {13E84779-125E-4B76-8C0D-1F5DB92EFE0F}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:10.062 [INFO] xcl1: Pruning SCSI disk
> > > > '\\.\PHYSICALDRIVE1', on Bus '4' and Port '2'; at 'SCSI Tid 1, SCSI
> > > > Lun 0' (hr=00000000, {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:10.109 [INFO] xcl1: The physical disk "Disk D:"
> > > > cannot be managed because it is on the same storage bus as the boot
> > > > disk. (hr=00000000, {13E84779-125E-4B76-8C0D-1F5DB92EFE0F},
> > > > {1EFA8906-A36E-43BF-AF65-7F74413672EE}, 1, 1, 1), The cluster cannot
> > > > manage physical disks that are on the same storage bus as the volume
> > > > that contains the operating system because other nodes connected to
> > > > the storage bus cannot distinguish between these volumes and volumes
> > > > used for data.
> > > > 2004-10-04 21:02:10.156 [INFO] xcl1: The physical disk "Disk D:"
> > > > cannot be managed because it is on the same storage bus as the boot
> > > > disk. (hr=00000000, {13E84779-125E-4B76-8C0D-1F5DB92EFE0F},
> > > > {1EFA8906-A36E-43BF-AF65-7F74413672EE}, 1, 1, 1), The cluster cannot
> > > > manage physical disks that are on the same storage bus as the volume
> > > > that contains the operating system because other nodes connected to
> > > > the storage bus cannot distinguish between these volumes and volumes
> > > > used for data.
> > > > 2004-10-04 21:02:10.203 [INFO] xcl1: Pruning SCSI disk
> > > > '\\.\PHYSICALDRIVE0', on Bus '4' and Port '2'; at 'SCSI Tid 0, SCSI
> > > > Lun 0' (hr=00000000, {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:10.250 [INFO] xcl1: The physical disk "Disk C:"
> > > > cannot be managed because it is on the same storage bus as the boot
> > > > disk. (hr=00000000, {13E84779-125E-4B76-8C0D-1F5DB92EFE0F},
> > > > {39C7A02C-0713-4694-9652-48C9313A9663}, 1, 1, 1), The cluster cannot
> > > > manage physical disks that are on the same storage bus as the volume
> > > > that contains the operating system because other nodes connected to
> > > > the storage bus cannot distinguish between these volumes and volumes
> > > > used for data.
> > > > 2004-10-04 21:02:10.312 [INFO] xcl1: The physical disk "Disk C:"
> > > > cannot be managed because it is on the same storage bus as the boot
> > > > disk. (hr=00000000, {13E84779-125E-4B76-8C0D-1F5DB92EFE0F},
> > > > {39C7A02C-0713-4694-9652-48C9313A9663}, 1, 1, 1), The cluster cannot
> > > > manage physical disks that are on the same storage bus as the volume
> > > > that contains the operating system because other nodes connected to
> > > > the storage bus cannot distinguish between these volumes and volumes
> > > > used for data.
> > > > 2004-10-04 21:02:10.390 [INFO] [SRV] The cluster service is not
> > > > running. Creating a dummy Majority Node Set resource.
> > > > 2004-10-04 21:02:11.000 [INFO] xcl1: The following networks will not
> > > > be managed by the cluster: (hr=00000000,
> > > > {036BF567-2377-4BB3-8AE1-E4104E2EB3C5},
> > > > {00AF4C3F-47D5-4E6A-9EF0-6D719A32EE5C}, 1, 1, 1), The network adapters
> > > > shown cannot be managed by the cluster. Please ensure that they have
> > > > valid TCP/IP configurations and are connected to the network. Once
> > > > these network adapters have a valid TCP/IP configuration they will be
> > > > automatically added to the cluster.
> > > >
> > > > 2004-10-04 21:02:12.296 [WARN] xcl1: Local quorum 'is not' the quorum
> > > > device. (hr=0x000001, {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:12.343 [INFO] xcl1: Located a quorum-capable resource
> > > > "Local Quorum". (hr=00000000, {01297D4D-0C7C-44B1-AECE-604C710A65CC},
> > > > {D29FB842-F9F9-44C1-A04B-C73BFC810C66}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:12.406 [INFO] xcl1: (null) (hr=00000000,
> > > > {FDC75680-7DBB-42CA-8003-E4CDB01FF062},
> > > > {6279EE6C-E99C-47CA-A61E-039C75C5C982}, 0, 6, 2), (null)
> > > > 2004-10-04 21:02:12.468 [WARN] xcl1: Majority Node Set 'is not' the
> > > > quorum device. (hr=0x000001, {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:12.531 [INFO] xcl1: Located a quorum-capable resource
> > > > "Majority Node Set". (hr=00000000,
> > > > {01297D4D-0C7C-44B1-AECE-604C710A65CC},
> > > > {511E37C6-6EA1-4737-B977-D8B911EB0A56}, 1, 1, 1), (null)
> > > > 2004-10-04 21:02:12.578 [INFO] xcl1: (null) (hr=00000000,
> > > > {FDC75680-7DBB-42CA-8003-E4CDB01FF062},
> > > >
> > > > (hr=00000000, {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:04:05.421 [INFO] xcl1: The physical disk "Disk D:"
> > > > cannot be managed because it is on the same storage bus as the boot
> > > > disk. (hr=00000000, {13E84779-125E-4B76-8C0D-1F5DB92EFE0F},
> > > > {579AFE20-32FF-4409-A3FB-9F5169210567}, 1, 1, 1), The cluster cannot
> > > > manage physical disks that are on the same storage bus as the volume
> > > > that contains the operating system because other nodes connected to
> > > > the storage bus cannot distinguish between these volumes and volumes
> > > > used for data.
> > > > 2004-10-04 21:04:05.468 [INFO] xcl1: The physical disk "Disk D:"
> > > > cannot be managed because it is on the same storage bus as the boot
> > > > disk. (hr=00000000, {13E84779-125E-4B76-8C0D-1F5DB92EFE0F},
> > > > {579AFE20-32FF-4409-A3FB-9F5169210567}, 1, 1, 1), The cluster cannot
> > > > manage physical disks that are on the same storage bus as the volume
> > > > that contains the operating system because other nodes connected to
> > > > the storage bus cannot distinguish between these volumes and volumes
> > > > used for data.
> > > > 2004-10-04 21:04:05.531 [INFO] xcl1: Pruning SCSI disk
> > > > '\\.\PHYSICALDRIVE0', on Bus '4' and Port '2'; at 'SCSI Tid 0, SCSI
> > > > Lun 0' (hr=00000000, {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > > 2004-10-04 21:04:05.578 [INFO] xcl1: The physical disk "Disk C:"
> > > > cannot be managed because it is on the same storage bus as the boot
> > > > disk. (hr=00000000, {13E84779-125E-4B76-8C0D-1F5DB92EFE0F},
> > > > {C6DBB8DA-B17C-4712-8A2A-DB6D9FBEDC76}, 1, 1, 1), The cluster cannot
> > > > manage physical disks that are on the same storage bus as the volume
> > > > that contains the operating system because other nodes connected to
> > > > the storage bus cannot distinguish between these volumes and volumes
> > > > used for data.
> > > > 2004-10-04 21:04:05.640 [INFO] xcl1: The physical disk "Disk C:"
> > > > cannot be managed because it is on the same storage bus as the boot
> > > > disk. (hr=00000000, {13E84779-125E-4B76-8C0D-1F5DB92EFE0F},
> > > > {C6DBB8DA-B17C-4712-8A2A-DB6D9FBEDC76}, 1, 1, 1), The cluster cannot
> > > > manage physical disks that are on the same storage bus as the volume
> > > > that contains the operating system because other nodes connected to
> > > > the storage bus cannot distinguish between these volumes and volumes
> > > > used for data.
> > > > 2004-10-04 21:04:05.718 [INFO] [SRV] The cluster service is not
> > > > running. Creating a dummy Majority Node Set resource.
> > > > 2004-10-04 21:04:05.812 [WARN] xcl1: [SRV] Enumerating resources.
> > > > Total Requested:10; Current enum index:0; Total Enums:4. (hr=0x000001,
> > > > {05AA0768-5F49-49CD-AFDC-96F9D51802D4},
> > > > {00000000-0000-0000-0000-000000000000}, 1, 1, 1), (null)
> > > >
> > > > So it appears that the problem is that the clustering service cannot
> > > > find the quorum disk. The OS part of the system which uses the raid 1
> > > > and embedded 5I raid controler the same storage bus location ( 4 ) as
> > > > the external scsi partitions which have an external 5I controller.(
> > > > d: and e:).
> > > >
> > > >
> > > > I have tried to remove and remake the array and partitions on the
> > > > storage through the smartstart cd from HP. But i cannot find a option
> > > > where i can assign a different bus.
> > > >
> > > > Can anyone give me a solution for this problem?
> > > >
> > > > Thnx in advance.



Relevant Pages

  • Re: Intel IXP420/425 BSP Compact Flash Driver
    ... PCMCIA controller driver for the PCMCIA one). ... bus directly which means the CF is working as a IDE HDD but you may need to ... the BSP does not include a compact flash driver. ... Devices/Compact Flash / PC Card Storage " driver from the catalog ...
    (microsoft.public.windowsce.platbuilder)
  • abandoned vehicle find !!
    ... old guys 73 bus breaks down, starts to work on it, decides to get to it later, doesn't, puts it in storage for about 10 years, dies, widow doesn't pay the storage fee, storage company gets ownership of the storage garage contents and discovers the bus. ...
    (rec.autos.makers.vw.aircooled)
  • Just Because...bus
    ... I am thinking about finding my bus a new home...it is a '74 Chevy ... industrial engine, stove, sink, propane setup, also setup for solar ... , runs good, has bunk beds, storage, pantry, queen ... storage in Willits, California...I am headed for Willits the first week ...
    (alt.gathering.rainbow)
  • Re: Magical Express and Tipping
    ... The bus driver is the baggage handler. ... You might also have incidental baggage handling tip expenses if you choose to check your bags into luggage storage at your hotel between room checkout time and bus pickup time. ...
    (rec.arts.disney.parks)