Re: workstations & server times

Tech Tip: Click here to run a free scan for Windows Errors and optimize PC performance



Hello param@xxxxxxxxxxxxxxxx,

The PDCEmulator is the domain time source, that you can configure with an external time server:

PDCEmulator:

w32tm /config /manualpeerlist:peers /syncfromflags:manual /reliable:yes /update

With "peers" you can set the time source, either DNS name (time.windows.com) or an ip address from a reliable time source.

Here you can find some of them:
http://www.pool.ntp.org/

All DC's sync with the PDCEmulator and the member servers and workstations sync with an available DC, mostly that one in their site.

Best regards

Meinolf Weber
Disclaimer: This posting is provided "AS IS" with no warranties, and confers no rights.
** Please do NOT email, only reply to Newsgroups
** HELP us help YOU!!! http://www.blakjak.demon.co.uk/mul_crss.htm


Hi all,

Is it possible to configure all member workstations & servers in our
domain to sync their date/time with a central server? We have 2 DCs
and either one would be OK We also have an ISA server on our network.
So would we have to open up any firewall permissions?

Any articles on how to do this would be greatly appreciated.

TIA!



.



Relevant Pages

  • Re: Change Domain Time Server
    ... Domain time sync is in this way, the PDCEmulator is the time source of the domain, all DC's sync with that machine, member servers and workstations choose one available DC for the sync. ... Net time is the older version form 2000. ... So the PDC is always the time server. ...
    (microsoft.public.windows.server.general)
  • Re: Configuring w32time
    ... Yes, the PDCEmulator is your SBS, no other DC can have the FSMO roles when SBS is used. ... The PDCemulator in a domain is always the time source and all other DC's sync with that one automatically. ... Personal i would configure the SBS to an external time source and reconfigure the clients to use the SBS as domain time server. ...
    (microsoft.public.windows.server.active_directory)
  • Re: system hangs- logging w32time errors
    ... Ethernet adapter Local Area Connection: ... the time service shouldn't create this kind of errors. ... The errors occur because you server has no external time ... With "peers" you can set the time source, ...
    (microsoft.public.windows.server.general)
  • Re: Time server
    ... and this server seems to be syncing externally fine. ... How to Synchronize an Internal Time Server with an External Source ... internal network's authoritative time source with a very precise external ... which provides the NIST Network Time service. ...
    (microsoft.public.windows.server.active_directory)
  • Re: Server time on DC time lags 1:30 sec from NTP source?
    ... Maybe you cna use another time source to get closer, personal i never realized this differences with our time. ... time server Server 2003 uses should be time-windows.com and not ... Time sync by client to DC ... packets, the client adjusts its local time based on the target (i.e., ...