Re: Cant restart WMI
From: Natalie Drest (charlystuangstabilack_at_yahoo.com)
Date: 02/20/05
- Next message: Michael Bednarek: "Re: Login script with admin priveleges"
- Previous message: Natalie Drest: "Cant restart WMI"
- In reply to: Natalie Drest: "Cant restart WMI"
- Next in thread: Peter Falz: "Re: Cant restart WMI"
- Messages sorted by: [ date ] [ thread ]
Date: 19 Feb 2005 18:08:53 -0800
After doing a little more poking around I found this suggestion:
%windir%\system32\wbem\mofcomp %windir%\system32\wbem\hnetcfg.mof
which resulted in the following:
Microsoft (R) 32-bit MOF Compiler Version 5.1.2600.1106
Copyright (c) Microsoft Corp. 1997-2001. All rights reserved.
Parsing MOF file: C:\WINDOWS\system32\wbem\hnetcfg.mof
MOF file has been sucessfully parsed
Sorting data in the repository...
An error occurred while opening the namespace for object 1 defined on
lines 16-19:
Error number: 0x80041015, Facility WMI
Description: Transport Failure
Compiler returned error 0x80041015