Re: Stop 7B post-FBA reboot
- From: "KM" <konstmor@xxxxxxxxxxxxxxxx>
- Date: Thu, 14 Apr 2005 19:08:25 -0700
Quentin,
Also, if you are using EWF (I can imagine only RAM REG since no mention in FBALog) on your image make sure it is initially disabled.
--
Regards,
KM, BSquare Corp.
> Quentin,
>
> The following lines look scary:
> 16:06:44 PM - [PnpEnumThread: InstallDevice] SetupDiCallClassInstaller Error: 0xe0000217, Device: Intel Processor
>
> 16:06:49 PM - [PnpEnumThread: InstallDevice] SetupDiCallClassInstaller Error: 0xe0000217, Device: Intel(R) 82801EB Ultra ATA
> Storage Controllers - 24DB
>
> 16:07:00 PM - [PnpEnumThread: InstallDevice] SetupDiCallClassInstaller Error: 0xe0000217, Device: Intel(R) 82801EB Ultra ATA
> Storage Controllers - 24D1
>
>
> Seems like on the first FBA round some critical device gets installed (or installed not properly) and you see the 7B error on next
> boot.
> Take a look at the SetupApi.log file to see why the error mentioned above appear.
>
>
> --
> Regards,
> KM, BSquare Corp.
>
>
> > Hello All.
> >
> > Firstly, I would like to thank everyone for making this a very informative
> > and useful forum; without it, there is no way I would be where I am today
> > with respect to XPe development.
> >
> > Last week I started to get a Stop 7B immediately after the FBA's reboot on
> > XPe images that used to work. Now the only image I can get to work is a
> > "Min Logon Sample Macro"; all of my test images from before crash as
> > described above. The only thing I can think of that has changed in this
> > time period is an XPe upgrad from SP1 to SP2.
> >
> > Attached is the FBALOG.TXT; could someone have a look at it and let me know
> > if there is anything that looks wrong?
> >
> > The only thing I can see is:
> > [FBAChangeDisplaySettings] Settings: [800, 600, 32, 60]
> > [FBAChangeDisplaySettings] Settings not found!
> >
> > But from what I remember, that was happening before I started getting the
> > 7B's.
> >
> > Quentin.
> >
> >
> >
>
>
.
- References:
- Stop 7B post-FBA reboot
- From: Quentin
- Re: Stop 7B post-FBA reboot
- From: KM
- Stop 7B post-FBA reboot
- Prev by Date: Re: Application starts too soon
- Next by Date: OK
- Previous by thread: Re: Stop 7B post-FBA reboot
- Next by thread: Re: Stop 7B post-FBA reboot
- Index(es):
Relevant Pages
|