Re: Win2003 not listening for NTP on Port 123
- From: "Tony" <wittley3231@xxxxxxxxxxx>
- Date: Sat, 25 Jun 2005 15:11:24 -0400
Configuring the Windows Time service to use an internal hardware clock
Warning If you use Registry Editor incorrectly, you may cause serious
problems that may require you to reinstall your operating system. Microsoft
cannot guarantee that you can solve problems that result from using Registry
Editor incorrectly. Use Registry Editor at your own risk.
To configure the PDC master without using an external time source, change
the announce flag on the PDC master. The PDC master is the server that holds
the forest root PDC master role for the domain. This configuration forces
the PDC master to announce itself as a reliable time source and uses the
built-in complementary metal oxide semiconductor (CMOS) clock. To configure
the PDC master by using an internal hardware clock, follow these steps: 1.
Click Start, click Run, type regedit, and then click OK.
2. Locate and then click the following registry subkey:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32Time\Config\Announce
Flags
3. In the right pane, right-click AnnounceFlags, and then click
Modify.
4. In Edit DWORD Value, type A in the Value data box, and then click
OK.
5. Quit Registry Editor.
6. At the command prompt, type the following command to restart the
Windows Time service, and then press ENTER:
net stop w32time && net start w32time
This appears to infer that windows 2000/2003 server is in fact a valid Time
source. Just ensure your hardware clock is correct obviously.
----------------------------------------------------------
<jwgoerlich@xxxxxxxxx> wrote in message
news:1119360684.261979.34310@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> We are configuring Win2003 domain controllers to be the primary network
> time source. All non-Windows servers are setup to use NTP. The Unix
> servers work fine but we are having some problems with the Netware
> servers. In diagnosing, I noticed that the domain controllers are not
> listening on port 123 (confirmed this with telnet and a port scanner.)
>
> Should Win2003 servers be listening on NTP port 123? If no, then why
> not?
>
> Thanks in advance,
>
> J Wolfgang Goerlich
>
.
- References:
- Win2003 not listening for NTP on Port 123
- From: jwgoerlich
- Win2003 not listening for NTP on Port 123
- Prev by Date: Re: is DHCP required when using two NIC's?
- Next by Date: Re: Network IP Address for Printer
- Previous by thread: Re: Win2003 not listening for NTP on Port 123
- Next by thread: losing connection... ?
- Index(es):