Date: Wed, 4 Aug 2004 05:51:02 -0700
Hello Trace,
Unfortunately the hotfix 870543 did not resolve the problem. I reinstalled BizTalk along with Rollup Package 1 and Hotfix 870543 but I still get the EDI Subsystem error messages. Is there anything else that can be done?
Very best regards,
Martin
""Trace Young"" wrote:
> Hello Martin,
>
> I believe that this behavior is addressed in the latest rollup fix for the
> BizTalk Server 2004 Base EDI Adapter (which is documented @
> http://support.microsoft.com/?id=870543) . Please open a support incident
> with Microsoft PSS to request this fix. Since you are requesting a fix for
> a known issue you will be issued a grace incident.
>
> Regards,
>
> Trace
> --------------------
> | I have encountered a critical bug in the base EDI adapter. For every EDI
> message (EDIFACT D93A) I create using the EDI Send Handler, the EDI
> Subsystem starts generating the error message shown below with a frequency
> of one error message / minute. Having sent 100 EDI messages, I receive 100
> error messages per minute. This occurs even though the EDI messages are
> created successfully in the outbound directory. And regardless of being
> successfully created, every EDI message also stays eternally active in HAT.
> However, the error messages keep flooding into the Event Viewer even after
> terminating all messages in HAT.
> |
> | Any help regarding this issue would be very much appreciated. I have
> already tried switching off the Trace EDI Adapter property on the Send
> Handler (as recommended in another trace) but unfortunately that did not
> resolve the problem.
> |
> | Best regards,
> |
> | Martin Westerlund
> |
> | The error message referred to above:
> |
> | Event Type: Error
> | Event Source: EDI Subsystem
> | Event Category: BizTalk Server 2004
> | Event ID: 23
> | Description:
> | Error encountered: ERROR (1030), interchangenr 10004 :
> | COM_SendMessage(): Cant make a connection to BizTalk for document #10004.
> Errorcode is -1030 ()
> |
> |
> |
>
> This posting is provided "AS IS" with no warranties,and confers no rights.
> Subscribe at
> http://support.microsoft.com/default.aspx?scid=/servicedesks/msdn/nospam.asp
> &SD=msdn
>
>
- Next message: Roger Austin: "Event log warning 10536"
- Previous message: David Robinson: "Logical functoid has gone wrong"
- In reply to: Trace Young: "RE: Base EDI adapter: COM_SendMessage eternal loop error"
- Next in thread: Trace Young: "RE: Base EDI adapter: COM_SendMessage eternal loop error"
- Reply: Trace Young: "RE: Base EDI adapter: COM_SendMessage eternal loop error"
- Messages sorted by: [ date ] [ thread ]
Relevant Pages
|