Registry File Failure BSOD after RAID repair



SBS2K with Adaptec 1200A IDE RAID 1

After replacing a failed disk, the RAID 1 duplicated the info to the new
mirror disk from the existing survivor. All booted up fine (well, to be
exact, I had disabled all the Trend stuff the previous day before the
grinding drive finally failed, so it booted up without the Trend AV
modules).

However, when I enabled the Trend and rebooted for the server to start up
with all progs blazing, I got a 'one of yourd disks needs to be checked for
consistency' and then a few 'deleting corrupt attribute record from file
record segment' type messages, before the OS fully loaded.

In fact, it never loaded again...I now just get BSOD:
STOP: c0000218 (Registry file failure)
The reg cannot load teh hive (file):
\SystemRoot\System32\Config\SOFTWARE
or its log or alternate.
It is corrupt, absent or not writable.

Have tried with the new mirror drive alone, no go either. But when I take
the drive out and attach it to a normal PC, all seems to read fine.

Any ideas?


.



Relevant Pages

  • Re: Making mirror disk bootable
    ... Currently I'm booting to the mirrored disk of my server as the primary ... Use xcopy.exe to copy the source to the target. ... Boot the server with only the target connected. ... the mirror disk in any way until Step 6. ...
    (microsoft.public.windows.server.general)
  • Re: Mirroring Boot disk problems using VxVM
    ... The best way for start point of root slice in a encaspulated volume like a rootvol, is start from cylinder 2 because with cyl 0 and 1 VxVM can protect the block zero. ... Private region must to be start at start of the disk, vxvm when have a root slice that don't start from cyl 2, create a little volume called rootdiskPriv and a subdisk called "rootdisk-B0". ... I see that the disk 2 is a mirror disk because after encapsulation veritas can't modify the partition table, but can when you mirror a disk with vxdiskadm command. ...
    (comp.sys.sun.admin)
  • SUMMARY: Replacing disks in DiskSuite
    ... As we use ufsdump to back up the disk I decided the quickest and easiest way ... Brought the primary disk partitions into SDS and then created the mirrors. ... > Subject: Replacing disks in DiskSuite ... > Remove and replace the mirror disk ...
    (SunManagers)
  • More about: metadevice failed: invoke metareplace
    ... metareplace: wtn450: d1: unknown metadevice type ... metareplace as it was a new brand drive. ... syslog I think there is a single bad block in the disk (Error Block: ... failed disk, wait for a new disk, reboot and recreate the mirror. ...
    (SunManagers)
  • Re: Oracle Database 10g R2 and RHEL4 Update 3
    ... ASM automatically rebalances and effectively stripes over all disks ... If a disk fails, the data ... ASMLIB, remove the failed disk from the OS, physically remove the failed ... adding storage to ASM is easy and managed entirely by Oracle. ...
    (comp.databases.oracle.server)